Dinosaur Electronics Universal Ignitor Board - For Suburban® and Atwood® / HydroFlame® Furnaces with Fan Control Features FAN50PLUSPINS
Product Description: FAN50PLUSPINS
ONLINE DROPSHIP PRICE ONLY
The FAN 50 Plus Pins is designed to replace the new Suburban® and Atwood® / HydroFlame® Fan Control boards as well as maintain backward compatibility with the Fan 50 Plus, and UIB Fan Control boards which have been available since 1994. This board can also be used to upgrade older furnaces to add the Fan Control feature.
The basic purpose of a Fan Control Ignitor Board is to shut the fan motor off if the board fails to sense a flame after the third ignition try. Thus, battery drain is reduced and the needless blowing of cold air is eliminated.
The FAN 50 Plus Pins , after shutting the fan motor off, will wait for 1 hour and repeat the whole sequence again before permanent shut down.
For 12 VDC Furnaces ONLY!
The "Fan Control" feature MUST BE USED for proper operation of this board.
Universal Ignitor Boards are for use in Furnaces, Refrigerators & Water Heaters. The UIB series boards come ready for use in Furnaces or a jumper on the board can be cut to make the board instant fire for use in Refrigerators or Water heaters. These universal 12 Volt DC ignitor boards are certified by Testing Engineers International to meet UL 372 and UL 353 specifications for use in the RV industry. The universal ignitor boards are all "electrically" identical but "mechanically" different for convenient installation
*Note: Fan control boards should not be used in DuoTherm® 900 series furnaces that have the thermostat in the ground circuit. DuoTherm® furnaces can be rewired to move the thermostat from the ground side of the circuit to the positive side of the circuit so that the Fan control features of the Fan control or FAN 50 Plus Pins board can be used.
- Size: 3.25" x 4.25"
- Works in 12 VDC furnaces*
- Removable jumper for Instant fire operation in water heaters and refrigerators
- Superior Construction - "Plated and soldered through holes" to virtually eliminate intermittent connections.
- 3 Try - Tries 3 times to ignite gas, with appropriate purge cycles before going into lockout.
- Shuts the fan motor OFF a minute and a half after the 3rd ignition try fails to sense a flame
- Waits one hour and tries the cycle again before locking out requiring the thermostat to be reset.
- Microcontroller - Highly reliable microcontroller for accurate and stable operation.
- Diagnostic LEDs - UIB Series Igntior boards all have diagnostic LEDs to aid in troubleshooting
- Fuse protection - Replaceable 5 Amp automotive fuse to protect the board from short circuits on the Valve and NC terminals
- Made in the USA - All of the circuit boards are made in the US with quality first, in mind. Every board is tested before packaging.
- Three Year Warranty - Click this link more Information on Dinosaur's Outstanding 3 year Warranty.
-
Duo-Therm/ Hydro-Flame/ Suburban Furnaces
Propane is an explosive gas! Ignitor boards should be installed by trained service technicians.
MFG’S Part # | Dinosaur # | MFG’S Part # | Dinosaur# |
Mark 10-12-1-12-12-E340 | UIB S POST | 6743 | UIB S |
Mark 10-12-2-5.5-5.5-E310 | UIB L POST | 7020 | UIB S |
Mark 10-12-2-5.5-5.5-E340 | UIB S POST | 9042 | UIB S |
Mark 10-12-2-7-7-E312 | UIB L | 12500 | UIB S |
Mark 10-12-2-12-12-E310 | UIB L POST | 31501 Kit with 33488 | Fan 50 Plus Pins |
Mark 10-12-15-7-7-E002 | UIB L | 33488 (included in 31501 Kit) | Fan 50 Plus Pins |
Mark 10DM-12-1-12-12-E3002 | UIB S | & a 6 pin header connector | |
Mark 10DN-12-1-12-12-E3022 | UIB S | 35119 | UIB 24VAC |
Mark 10DN-12-1-5.5-5.5-E3022 | UIB S | 36716 | UIB S |
Mark 10DN-12-1-7-7-E3002 | UIB S | 37515 | UIB 24VAC |
Mark 10N-12-1-12-12-E342 | UIB S | 37874 | UIB S |
Mark 10N-12-1-5.5-5.5-E222 | UIB S | 37875 | Fan 50 Plus Pins |
Mark 10N-12-1-5.5-5.5-E322 | UIB S | 38242 | None |
Mark 14-12-20-7-7-E002 | UIB L | 91226 Atwood AC/Gas | UIB 64 |
Mark 14N-12-15-7-7-E202 | UIB S | ||
Mark 50N-12-3-15-7-7-E3002 | NONE | 91315 | UIB S POST |
2 Stage Furnace- Ground Lug | 91731 | UIB S POST | |
Mark 50N-12-3-3-7-10-0-E23062 | NONE | 93253 Atwood AC/Gas | UIB S |
2 Stage Furnace- Ground Lug | |||
Mark 51N-12-3-3-7-10-0-E23062 | UIB 64 | 6713 | UIB S |
AC/Gas Water Heater | 93256 | UIB S | |
05-152435-003 | UIB L POST | 93257 | UIB S |
05-152435-103 | UIB L POST | 93851 AC/Gas | UIB 64 |
05-152436-053 |
UIB L POST |
||
05-152436-103 | UIB L POST | 93865 | UIB S |
05-159000-003 | UIB L | 230481 | UIB L |
05-159000-053 | UIB L | 230483 | UIB L |
05-159000-103 | UIB L | 230505 | UIB 24VAC |
05-159003-253 | UIB L POST | 230587 | UIB L |
05-159003-255 | UIB L POST | 230608 | UIB 24VAC |
05-159006-753 | UIB L POST | 231427 | UIB S |
05-159006-755 | UIB L POST | 231741 | UIB S |
05-159007-103 | UIB L | 231741-2 | UIB S |
05-169002-003 | UIB 24VAC | 232182 | UIB S |
05-169003-103 | UIB 24VAC | 232391 | UIB S |
05-169005-123 | UIB L POST | 232490 | UIB S |
05-259000-153 | UIB L | 232582 | UIB S |
05-299000-153 | UIB 24VAC | 232613 | Fan 50 Plus Pins |
05-299004-153 | UIB 24VAC | 232614 | Fan 50 Plus Pins |
05-299010-753 | UIB S | 232659 | UIB S |
05-299024-153 | UIB 24VAC | 232838 | UIB 24VAC |
05-299026-153 | UIB 24VAC | 315526 | UIB L |
05-306435-153 | UIB S | 316019 | UIB 24VAC |
05-309001-153 | UIB S | 318816 | UIB L |
05-309002-153 | UIB S | 520427 Kit with 231427 | UIB S |
05-309008-153 | UIB S | 520741 Kit with 231741 | UIB S |
05-309009-153 | UIB S | 520814 Kit with ? | UIB S |
05-309014-153 | UIB S | 520820 Kit with 232613 | Fan 50 Plus Pins |
05-309017-153 | UIB S | 618652 | UIB S |
05-309017-158 | UIB S | 61525022 | UIB L POST |
05-309022-153 | UIB S | 61549522 | UIB L POST |
05-30DSI Series | UIB S | 61688922 | UIB S |
05-505650-153 | UIB S | 61717037 | UIB S |
05-525900-113 | UIB S | ARM91315 | UIB S POST |
1721 | UIB L | BLUE BOY | UIB S |
3521 | UIB L | FA7615 | UIB L POST |
3802 | UIB S | MPD91731 | UIB L POST |
3845 | UIB S | RAM | UIB S |
4322-321 | UIB L POST | RUBY | UIB S |
5119 | UIB 24VAC | 35-615920-113 24VAC W/FAN | UIB 24VAC Fan Control |
6215 | UIB S | 35-615931-113 24VAC W/FAN |
UIB 24VAC Fan Control |
6245 | UIB S |